DELTA

DELTA
Biến tần Delta, PLC Delta, Servo Delta, HMI Delta

Cảm biến lưu lượng IFM SA5000 100 bar

Cảm biến lưu lượng IFM SA5000

Cảm biến lưu lượng IFM SA5000 100 bar

               Cảm biến lưu lượng IFM SA5000 100 bar

Thông số kỹ thuật cảm biến lưu lượng IFM SA5000 

Product characteristics

Number of inputs and outputs

Number of digital outputs: 2; Number of analogue outputs: 1

Process connection

threaded connection M18 x 1,5 internal thread

Application

Special feature

Gold-plated contacts

Media

water; glycol solutions; air; oils

Note on media

low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)

high-viscosity oils with viscosity: > 40 mm²/s (40 °C)

Medium temperature [°C]

-20...90

Pressure rating [bar]

100

Pressure rating [Mpa]

10

MAWP (for applications according to CRN) [bar]

100

Electrical data

Operating voltage [V]

18...30 DC

Current consumption [mA]

< 100

Protection class

III

Reverse polarity protection

yes

Power-on delay time [s]

10

Inputs / outputs

Number of inputs and outputs

Number of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs

2

Output signal

switching signal; analogue signal; frequency signal; IO-Link; (configurable)

Electrical design

PNP/NPN

Number of digital outputs

2

Output function

normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]

250

Number of analogue outputs

1

Analogue current output [mA]

4...20; (scalable)

Max. load [Ω]

350

Short-circuit protection

yes

Type of short-circuit protection

pulsed

Overload protection

yes

Frequency of the output [Hz]

0...1000

Measuring/setting range

Probe length L [mm]

45

Operating mode

relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended)

Note on factory setting

Operating mode: relative

Temperature monitoring

Measuring range [°C]

-20...90

Resolution [°C]

0.2

Liquid media - absolute operating mode

Setting range [m/s]

0.04...3

Greatest sensitivity [m/s]

0.04...3

Liquid media - relative operating mode

Setting range [m/s]

0.04...6

Greatest sensitivity [m/s]

0.04...3

Gases - operating mode "absolute"

Setting range [m/s]

0...100

Greatest sensitivity [m/s]

30...100

Gases - operating mode "relative"

Setting range [m/s]

0...200

Greatest sensitivity [m/s]

30...100

Accuracy / deviations

Temperature drift [cm/s x 1/K]

0,003 m/s x 1/K (< 20 °C; > 70 °C)

Temperature gradient [K/min]

100

Absolute operating mode

Repeatability

0,05 m/s; (water; flow velocity: 0,05...3 m/s)

Relative operating mode

Accuracy

± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)

Repeatability

0,05 m/s; (water; flow velocity: 0,05...3 m/s)

Temperature monitoring

Temperature drift

± 0,005 K/°C

Accuracy [K]

± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s)

Response times

Response time [s]

0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)

Temperature monitoring

Dynamic response T05 / T09 [s]

1,5 (T09); (water; flow velocity: 0,3...3 m/s)

Software / programming

Parameter setting options

hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour

Interfaces

Communication interface

IO-Link

Transmission type

COM2 (38,4 kBaud)

IO-Link revision

1.1

SDCI standard

IEC 61131-9

Profiles

Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis

SIO mode

yes

Required master port type

A

Process data analogue

2

Process data binary

2

Min. process cycle time [ms]

3

Supported DeviceIDs

Type of operation

DeviceID

Factory setting / ModE = (REL)

533

ModE = (LIQU)

540

ModE = (GAS)

547

Operating conditions

Ambient temperature [°C]

-40...80

Storage temperature [°C]

-40...100

Protection

IP 65; IP 67

Tests / approvals

EMC

DIN EN 60947-5-9

Shock resistance

DIN EN 60068-2-27

50 g (11 ms)

Vibration resistance

DIN EN 60068-2-6

20 g (10...2000 Hz)

MTTF [years]

132

UL approval

UL Approval no.

I003

Mechanical data

Weight [g]

314

Materials

stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30

Materials (wetted parts)

stainless steel (1.4404 / 316L); Gasket: FKM

Process connection

threaded connection M18 x 1,5 internal thread

Displays / operating elements

Display

Display unit

6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)

switching status

2 x LED, yellow

measured values

alphanumeric display, red/green 4-digit

Remarks

Remarks

MW = measured value

MEW = Final value of the measuring range

Pack quantity

1 pcs.

Electrical connection

Connection

Connector: 1 x M12; coding: A; Contacts: gold-plated

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA5000-01 — 26.04.2021 — 

 Mọi thông tin chi tiết liên hệ 0968 445 343 gặp a Tài để biết thêm thông tin chi tiết.